©Endress+Hauser
©Endress+Hauser
Alkalmazási terület
CYK10 guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling shows no contact corrosion and guarantees galvanic isolation of transmitter and medium. Simply forget about limited cable length, interfering potentials or moisture and benefit from completely safe and reliable signal transmission.
The Memosens data cable CYK10 is applied in Memosens systems measuring the following parameters:
Előnyök
Maximum process safety through non-contact, inductive and digital signal transmission: No contact corrosion, absolutely watertight, no interference potential.
Increased availability of the measuring point: Digital data transmission provides an automatic error message if the signal is lost.
More flexibility in plant planning and installation: Cable length up to 100 m is possible.
Approved for hazardous area use.
Szerezze be ezt a terméket egy csomag részeként
Egyszerű termékek
Könnyen kiválasztható, telepíthető és kezelhető
Műszaki kiválóság
Egyszerűség
Alaptermékek
Megbízható, robusztus és kevés karbantartást igényel
Műszaki kiválóság
Egyszerűség
Műszaki kiválóság
Egyszerűség
Speciális termékek
Nagy igénybevétellel járó alkalmazásokhoz tervezve
Műszaki kiválóság
Egyszerűség
FLEX választék
Műszaki kiválóság
Egyszerűség
Fundamental választék
Eleget tesz az Ön alapvető mérési igényeinek
Műszaki kiválóság
Egyszerűség
Lean választék
Könnyen kezeli az Ön alapvető folyamatait
Műszaki kiválóság
Egyszerűség
Extended választék
Innovatív technológiákkal optimalizálja az Ön folyamatait
Műszaki kiválóság
Egyszerűség
Xpert választék
Megoldás az Ön legnagyobb kihívást jelentő alkalmazásaihoz
Műszaki kiválóság
Egyszerűség
Sikertörténetek
An automated system for pH measurements at AVR
AVR Waste in Botlek, Rotterdam, processes up to 1.7 million tons of residual waste per year. Discover how they optimized their pH measurement thanks to Endress+Hauser
Olvassa el a teljes történetet
Pure high quality beer and clean wastewater
Discover how Heineken meets all regulations to protect the brazilian environment with the Viomax CAS51D digital nitrate or SAC sensor from Endress+Hauser.
Olvassa el a teljes történetet
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Measuring range
High impedance cable not necessary
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Process pressure
max. 50 bar/725 psi at 135°C/275°F.
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals.
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter.
Characteristic
Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Mérési elv
Amperometric oxygen measurement
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 ... 135 °C (-13 ... 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Additional certifications
Also available as TÜV approved SIL version
Legtöbbször letöltött
Memosens CYK10
Magyar változat - 03/2022
ATEX/NEPSI Ex ic IIC T3/T4/T6 Gc
Biztonsági utasítások robbanásveszélyes környezetben lévő elektromos
berendezésekhez
EN
HU
BG CS DA DE EL ES ET FI FR HR IT LT LV NL PL PT RO SK SL SV ZH
31/03/2022
Nyelv:
Magyar
Változat:
31/03/2022
Fájlméret:
738.2 KB
Fájlnév:
XA02850CHU_0122-00.pdf
CYK10/11
Magyar változat - 12/2021
Memosens adatkábel
EN
HU
BG CS DA DE EL ES ET FI FR HR ID IT JA KO LT LV NL NO PL PT RO RU SK SL SV TH TR ZH
08/12/2021
28/02/2018
06/07/2016
28/08/2012
01/11/2011
Nyelv:
Magyar
Változat:
08/12/2021
Fájlméret:
664.7 KB
Fájlnév:
BA00118CHU_0520-00.pdf
53 dokumentumok
Technical Information
Memosens measuring cable and installation
accessories
CYK10 / CYK11
EN
HU
Cseh Német Spanyol French Olasz Holland Lengyel Orosz
01/12/2011
01/11/2001
Nyelv:
Angol
Változat:
01/12/2011
Fájlméret:
718.3 KB
Fájlnév:
TI00118CEN_1311.pdf
CYK10, CYK11
Technical Information
Memosens measurement cables
EN
HU
Német French Orosz
01/12/2011
Nyelv:
Angol
Változat:
01/12/2011
Fájlméret:
718.3 KB
Fájlnév:
TI01477C_TI00118CEN_1311.pdf
EN
HU
Bolgár Cseh Dán Német Görög Spanyol Észt Finn French Horvát Indonéz Olasz Japán Koreai Lithuanian Latvian Holland Norvég Lengyel Portugál Román Orosz Szlovák Szlovén Svéd Thai Török Kínai
08/12/2021
28/02/2018
06/07/2016
28/08/2012
01/11/2011
Nyelv:
Magyar
Változat:
08/12/2021
Fájlméret:
664.7 KB
Fájlnév:
BA00118CHU_0520-00.pdf
Memosens data cable CYK10
Safety instructions for electrical apparatus inexplosion-hazardous areas UK Ex II 1 G Ex ia IIC T3/T4/T6 Ga
Nyelv:
Angol
Változat:
08/12/2021
Fájlméret:
499.6 KB
Fájlnév:
XA02783CEN_0121-00.pdf
XA Memosens data cable CYK10
Safety instructions for electrical apparatus in explosion-hazardous areas
EN
HU
Portugál
23/09/2024
Nyelv:
Angol
Változat:
23/09/2024
Fájlméret:
513 KB
Fájlnév:
XA03307CEN_0124-00.pdf
FM IS Cl. I Div. I Gr. A, B, C and D Safety instructions for electrical apparatus in explosion-hazardous areas
Nyelv:
Angol
Változat:
15/03/2022
Fájlméret:
503.5 KB
Fájlnév:
XA02846CEN_0122-00.pdf
NEPSI Ex ia IIC T3/T4/T6 Ga Safety instructions for electrical apparatus in explosion-hazardous areas
Nyelv:
Angol
Változat:
29/03/2022
Fájlméret:
609.8 KB
Fájlnév:
XA02845CEN_0122-00.pdf
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safetyinstructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN
HU
Német French
11/11/2016
31/12/2011
01/04/2009
Nyelv:
Angol
Változat:
11/11/2016
Fájlméret:
3.7 MB
Fájlnév:
XA00079CA3_1416.pdf
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safetyinstructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN
HU
Német French Lengyel
22/02/2016
04/03/2015
14/01/2013
21/10/2010
01/12/2006
Nyelv:
Angol
Változat:
22/02/2016
Fájlméret:
4.3 MB
Fájlnév:
XA00376CA3_1616.pdf
Memosens data cable CYK10
Safety instructions for electrical apparatus inexplosion-hazardous areas
EN
HU
Német Japán
19/01/2021
Nyelv:
Angol
Változat:
19/01/2021
Fájlméret:
421.9 KB
Fájlnév:
XA02356CEN_0121.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
No spare parts available.
Az adatvédelem nagyon fontos számunkra
Sütiket használunk a böngészési élmény javítására, statisztikai adatok gyűjtésére a webhely működésének optimalizálása érdekében, valamint személyre szabott hirdetések vagy tartalmak közvetítésére.
Ha az „Összes elfogadása” lehetőségre kattint, Ön hozzájárul a sütik használatához.
További részletekért kérjük, tekintse meg a sütikre (cookie) vonatkozó irányelveinket .
Testreszabás
Csak az alapvetőek elfogadása
Összes elfogadása