Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
785 nm
Temperature: probe is non-contact; operating temp: 10 to 50 °C / 50 to 122 °F
The union between our Raman analyzers equipped with Rxn-46 bioprocess probe technology and the BioPAT® Spectro platform by Sartorius offers the market an ideal interface to high-throughput development through single-use commercial manufacturing. Our Raman bioprocessing probe technology has been adapted to fit Sartorius’s BioPAT® Spectro platform, utilizing the same probe design for Ambr® 15, Ambr® 250, & Biostat STR® bioreactors.
Cell culture: glucose, lactate, amino acids, cell density, titer, and more
Enables faster, easier, and more robust model building via integration with Ambr® 15 and Ambr® 250
Allows high-throughput process development which supports QbD
Provides a more efficient transfer to Biostat STR® for single-use manufacturing
Offers a scale-independent interface from 15 ml in the laboratory to 2000 L in the production suite
Requires no probe cleaning, sterilization, or frequent maintenance due to non-contact sampling
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Egyszerű termékek
Műszaki kiválóság
Egyszerűség
Alaptermékek
Műszaki kiválóság
Egyszerűség
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Speciális termékek
Műszaki kiválóság
Egyszerűség
Kombinálható
| FLEX választék | Műszaki kiválóság | Egyszerűség |
|---|---|---|
Fundamental választék Eleget tesz az Ön alapvető mérési igényeinek |
Műszaki kiválóság
|
Egyszerűség
|
Lean választék Könnyen kezeli az Ön alapvető folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Extended választék Innovatív technológiákkal optimalizálja az Ön folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Xpert választék Megoldás az Ön legnagyobb kihívást jelentő alkalmazásaihoz |
Műszaki kiválóság
|
Egyszerűség
Kombinálható |
System design and specifications for the Raman Rxn-46
calibration and verification kit
| EN | HU | ||
|
11/01/2024
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
11/01/2024 |
|
Fájlméret: |
400.4 KB |
|
Fájlnév: |
TI01765CEN_0123.pdf |
System design and specifications for the Raman Rxn-46 probe
| EN | HU | ||
|
29/10/2025
|
|
|
|
|
13/12/2024
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
29/10/2025 |
|
Fájlméret: |
1010.6 KB |
|
Fájlnév: |
TI01634CEN_0525.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-46 probe
| EN | HU | ||
|
29/10/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
11/01/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
29/10/2025 |
|
Fájlméret: |
1.3 MB |
|
Fájlnév: |
BA02170CEN_0525.pdf |
Commissioning, operation, and maintenance details for the
Raman Rxn-46 calibration and verification kit
| EN | HU | ||
|
11/01/2024
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
11/01/2024 |
|
Fájlméret: |
928.9 KB |
|
Fájlnév: |
BA02324CEN_0123.pdf |
Quick start guide for the Raman Rxn-46 probe
| EN | HU | ||
|
02/12/2024
|
|
|
|
|
11/01/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Nyelv: |
Angol |
|
Változat: |
02/12/2024 |
|
Fájlméret: |
529 KB |
|
Fájlnév: |
KA01550CEN_0424.pdf |
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).
|
Nyelv: |
Angol |
|
Változat: |
27/06/2024 |
|
Fájlméret: |
1.9 MB |
|
Fájlnév: |
PU01585CEN_0124.pdf |
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).
|
Nyelv: |
Cseh |
|
Változat: |
06/09/2024 |
|
Fájlméret: |
381.4 KB |
|
Fájlnév: |
PU01584CEN_0124_cz_view.pdf |
A Q&A about how our Raman spectroscopy analyzer systems
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
and Rxn-46 probe), powered by Kaiser Raman technology, integrates
with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for
high throughput and single use (SUB) bioprocessingin the
biopharmaceutical life science industry.
|
Nyelv: |
Angol |
|
Változat: |
08/12/2021 |
|
Fájlméret: |
943.7 KB |
|
Fájlnév: |
PU01446CEN_0121.pdf |
Graphic illustrating the core elements of Biopharma 4.0 including
product lifecycle stages, role of PAT/QbD, and 12 key advanced
technologies for scientists and process engineers in the Life
Sciences, applicable to Raman spectroscopy systems (Raman
Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and
sleeve, flow cell and flow bench, Raman optic system for single
use, and Raman calibration & verification kits).
|
Nyelv: |
Angol |
|
Változat: |
22/05/2025 |
|
Fájlméret: |
481.6 KB |
|
Fájlnév: |
PU01614CEN_0125.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Nyelv: |
Angol |
|
Változat: |
26/06/2025 |
|
Fájlméret: |
363.4 KB |
|
Fájlnév: |
PU01611CEN_0125.pdf |