Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Body: 316L stainless steel
Window: Proprietary material, optimized for bioprocesses
Surface finish: Ra 15 with Electropolish to ASME BPE SF4 finish
Adhesive: USP Class VI and ISO 10993 compatible
120 or 220 mm
4.73 or 8.67 inch
Autoclave, gamma irradiation
The bio sleeve is a critical consumable part for easy, real-time bioprocess measurements with maximum sterility and efficiency. It connects to a reusable, automatically aligned multi optic which pairs with an Rxn-10 probe. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactor setups.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance
Autoclavable, gamma sterilizable, and compatible with standard cleaning protocols
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
120 mm version is compatible with Endress+Hauser flow assembly CYA680
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Egyszerű termékek
Műszaki kiválóság
Egyszerűség
Alaptermékek
Műszaki kiválóság
Egyszerűség
Felső kategóriás termékek
Műszaki kiválóság
Egyszerűség
Speciális termékek
Műszaki kiválóság
Egyszerűség
Kombinálható
FLEX választék | Műszaki kiválóság | Egyszerűség |
---|---|---|
Fundamental választék Eleget tesz az Ön alapvető mérési igényeinek |
Műszaki kiválóság
|
Egyszerűség
|
Lean választék Könnyen kezeli az Ön alapvető folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Extended választék Innovatív technológiákkal optimalizálja az Ön folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Xpert választék Megoldás az Ön legnagyobb kihívást jelentő alkalmazásaihoz |
Műszaki kiválóság
|
Egyszerűség
Kombinálható |
System design and specifications for the multi optic calibration
and verification kit
EN | HU | ||
26/06/2023
|
|
|
Nyelv: |
Angol |
Változat: |
26/06/2023 |
Fájlméret: |
478.7 KB |
Fájlnév: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | HU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
467.9 KB |
Fájlnév: |
TI01635CEN_0322.pdf |
System design and specifications for the Raman Rxn-10 probe
EN | HU | ||
13/11/2024
|
|
|
Nyelv: |
Angol |
Változat: |
13/11/2024 |
Fájlméret: |
929.9 KB |
Fájlnév: |
TI01629CEN_0424.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | HU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
1.8 MB |
Fájlnév: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
EN | HU | ||
02/12/2024
|
|
|
Nyelv: |
Angol |
Változat: |
02/12/2024 |
Fájlméret: |
1.2 MB |
Fájlnév: |
BA02160CEN_0424.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
EN | HU | ||
26/06/2023
|
|
|
Nyelv: |
Angol |
Változat: |
26/06/2023 |
Fájlméret: |
996.4 KB |
Fájlnév: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Quick start guide for the Raman Rxn-10 probe
Nyelv: |
Angol |
Változat: |
02/12/2024 |
Fájlméret: |
1.6 MB |
Fájlnév: |
KA01546CEN_0424.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | HU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Nyelv: |
Angol |
Változat: |
31/05/2023 |
Fájlméret: |
1 MB |
Fájlnév: |
KA01551CEN_0322.pdf |
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).
Nyelv: |
Cseh |
Változat: |
06/09/2024 |
Fájlméret: |
381.4 KB |
Fájlnév: |
PU01584CEN_0124_cz_view.pdf |
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).
Nyelv: |
Angol |
Változat: |
27/06/2024 |
Fájlméret: |
1.9 MB |
Fájlnév: |
PU01585CEN_0124.pdf |