Specifikációk áttekintése
-
Laser wavelength
532 nm
-
Hazardous area certifications
ATEX, CSA, IECEx
Alkalmazási terület
The Raman Rxn-30 probe has cross-industry appeal for its robust gas-phase headspace monitoring, in situ measurements, and material compatibility. Certified for use in hazardous area environments, the Raman Rxn-30 probe can be inserted directly into processes with temperatures up to 150 degrees Celsius and pressures up to 68.9 barg (1,000 psig). It is available with a variety of mounting options for maximum installation and sampling flexibility.
Chemical: ammonia, methanol, HyCO, reaction monitoring, blending, catalysis
Polymer: polymerization reaction monitoring
Gas-phase streams in refining: hydrogen production and recycle fuel blending, fuel characterization
Power & Energy: IGCC power plants, gas turbines
Pharmaceutical: API reaction monitoring, drying
Food & Beverage: fermentations, offgas, volatiles
Előnyök
Reliable, quantitative gas-phase measurements
In situ measurement/no transfer lines or fast loops required
Can be directly inserted into processes with temperatures up to 150 °C and 68.9 barg (1,000 psig)
Industry standard installation options
Direct insertion, side insertion, or sample loop
Suitable for hazardous area/classified environments
Extended választék
-
Felső kategóriás termékek
- Rendkívül funkcionális és kényelmes
Műszaki kiválóság
Egyszerűség
-
Egyszerű termékek
- Könnyen kiválasztható, telepíthető és kezelhető
Műszaki kiválóság
Egyszerűség
-
Alaptermékek
- Megbízható, robusztus és kevés karbantartást igényel
Műszaki kiválóság
Egyszerűség
-
Felső kategóriás termékek
- Rendkívül funkcionális és kényelmes
Műszaki kiválóság
Egyszerűség
-
Speciális termékek
- Nagy igénybevétellel járó alkalmazásokhoz tervezve
Műszaki kiválóság
Egyszerűség
Kombinálható
FLEX választék | Műszaki kiválóság | Egyszerűség |
---|---|---|
Fundamental választék Eleget tesz az Ön alapvető mérési igényeinek |
Műszaki kiválóság
|
Egyszerűség
|
Lean választék Könnyen kezeli az Ön alapvető folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Extended választék Innovatív technológiákkal optimalizálja az Ön folyamatait |
Műszaki kiválóság
|
Egyszerűség
|
Xpert választék Megoldás az Ön legnagyobb kihívást jelentő alkalmazásaihoz |
Műszaki kiválóság
|
Egyszerűség
Kombinálható |
Előd
-
-
Műszaki információ (TI)
Rxn-30 Raman spectroscopic probe Technical Information
System design and specifications for the Raman Rxn-30 probe
EN HU 13/12/2024Nyelv:
Angol
Változat:
13/12/2024
Fájlméret:
1.5 MB
Fájlnév:
TI01632CEN_0323.pdf
-
-
-
Használati útmutató (BA)
Rxn-30 Raman Spectroscopic Probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-30 probeEN HU 02/12/2024Nyelv:
Angol
Változat:
02/12/2024
Fájlméret:
2.4 MB
Fájlnév:
BA02168CEN_0323.pdf
-
-
-
Rövid útmutató (KA)
Rxn-30 Raman spectroscopic probe Brief Operating Instructions
Quick start guide for the Raman Rxn-30 probe
Nyelv:
Angol
Változat:
02/12/2024
Fájlméret:
1.4 MB
Fájlnév:
KA01548CEN_0323.pdf
-
-
-
Ex biztonsági utasítás (XA)
Rxn-30 Raman spectroscopic probe Safety Instructions
Hazardous area certifications and installation instructions
for the Raman Rxn-30 probeEN HU 21/06/202408/08/2023Nyelv:
Angol
Változat:
21/06/2024
Fájlméret:
1.3 MB
Fájlnév:
XA02748CEN_0424.pdf
-
-
-
PU (Kiadvány)
Raman Rxn5 analyzer - Laser-based composition analysis
An overview brochure about our Raman Rxn5 analyzer (including
the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe),
a Raman spectroscopy analyzer system for gas phase measurements
powered by Kaiser Raman technology.Nyelv:
Angol
Változat:
28/10/2021
Fájlméret:
499.9 KB
Fájlnév:
PU01444CEN_0121.pdf
-
-
-
PU (Kiadvány)
Raman analyzer application guide for the oil & gas and chemical industries - Composition analysis of gas streams and LNG
A guide to our Raman spectroscopy analyzer and probe portfolio,
powered by Kaiser Raman technology, for composition analysis of
gas streams and LNG (includes the Raman Rxn4 analyzer, the
Raman Rxn5 analyzer, the Raman Rxn-30 probe, and
Raman Rxn-41 probe) in the chemical industry and oil & gas industry.Nyelv:
Angol
Változat:
08/12/2021
Fájlméret:
2.5 MB
Fájlnév:
PU01445CEN_0121.pdf
-
-
-
PU (Kiadvány)
Industry standards on gas quality - Raman Rxn5 analyzer (syngas/LNG) andRaman Rxn4 analyzer (LNG)
A list of industry gas quality standards that our Raman Rxn5
analyzer meets for syngas / LNG and our Raman Rxn4
analyzer meets for LNG.Nyelv:
Angol
Változat:
20/04/2022
Fájlméret:
432.5 KB
Fájlnév:
PU01463CEN_0122.pdf
-
-
-
PU (Kiadvány)
石油・ガスおよび化学産業向け ラマン分光計アプリケーションガイド - ガスストリームおよびLNGの組成分析
化学産業および石油・ガス産業におけるガスストリームおよび LNG
の組成分析用(Raman Rxn4 アナライザー、Raman Rxn5 アナライザ
ー、Raman Rxn-30 プローブ、Raman Rxn-41 プローブを含む)、
Kaiser Raman テクノロジーによるラマン分光アナライザーおよび
プローブ製品ラインアップのご案内です。Nyelv:
Japán
Változat:
13/05/2024
Fájlméret:
4.2 MB
Fájlnév:
PU01445CJA_0121_RamanAnalyzer_AppGuide_OilGas_ChemInd.pdf
-
-
-
PU (Kiadvány)
Raman Rxn-30 probe - Gas phase analysis
An overview brochure about the Raman Rxn-30 probe, a
Raman spectroscopy probe for gas phase measurement
powered by Kaiser Raman technology in the Oil & Gas
industry and Chemical industry.Nyelv:
Angol
Változat:
20/01/2022
Fájlméret:
489.6 KB
Fájlnév:
PU01452CEN_0122.pdf
-
-
-
Innováció (IN)
Raman technology for the chemical industry - Reliable composition measurement of chemical process streams
An overview brochure about our Raman spectroscopy analyzer systems,
powered by Kaiser Raman technology, for the chemical industry
(includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe,
Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).Nyelv:
Angol
Változat:
18/10/2021
Fájlméret:
10.6 MB
Fájlnév:
IN01223CEN_0121.pdf
-