©Endress+Hauser
Raman Rxn5 analyzer
Specifikációk áttekintése
Alkalmazási terület
The Raman Rxn5 process analyzer is an industry-leading, turn-key, laser-based analyzer powered by Kaiser Raman technology. It provides quantitative chemical composition measurements using Raman spectroscopy. The design of the Raman Rxn5 incorporates customer requirements for serviceability and hazard-area certification, provides a compact footprint, and minimizes utilities consumption. The high optical efficiency of the analyzer makes it ideal for typical gas-phase sample measurements.
Process measurement points:
Typical industries:
Előnyök
Non-destructive analysis of gases, including homonuclear diatomics (H2 , N2 , O2 )
Compact, smaller than most wall-mount gas chromatographs (GCs)
Can replace up to four traditional analyzers with a single base unit and four probes
Rugged with minimal utility requirements, no sample transport, and no consumables (columns, valves, gases, pumps)
Minimal analyzer technician time with maximum technician safety (no toxic gases are transported to the analyzer)
Measures four streams simultaneously for faster multi-channel results
-20 to +50 °C operating environment
Extended választék
Műszaki kiválóság
Egyszerűség
©Endress+Hauser
Egyszerű termékek
Könnyen kiválasztható, telepíthető és kezelhető
Műszaki kiválóság
Egyszerűség
Alaptermékek
Megbízható, robusztus és kevés karbantartást igényel
Műszaki kiválóság
Egyszerűség
Műszaki kiválóság
Egyszerűség
Speciális termékek
Nagy igénybevétellel járó alkalmazásokhoz tervezve
Műszaki kiválóság
Egyszerűség
FLEX választék
Műszaki kiválóság
Egyszerűség
Fundamental választék
Eleget tesz az Ön alapvető mérési igényeinek
Műszaki kiválóság
Egyszerűség
Lean választék
Könnyen kezeli az Ön alapvető folyamatait
Műszaki kiválóság
Egyszerűség
Extended választék
Innovatív technológiákkal optimalizálja az Ön folyamatait
Műszaki kiválóság
Egyszerűség
Xpert választék
Megoldás az Ön legnagyobb kihívást jelentő alkalmazásaihoz
Műszaki kiválóság
Egyszerűség
Loading alternative products
Sikertörténetek
Measuring hydrogen quality in real time
Enapter uses optical analytical measurement technology from Endress+Hauser to determine the purity of hydrogen produced. Find out more!
Olvassa el a teljes történetet
LNG: truck loading
Find out how to accurately measure the composition of LNG at truck loading with the use of a Raman Rxn4 analyzer.
Olvassa el a teljes történetet
Temperature
Operating: -20 to 50 °C / -4 to 122 °F Recommended storage: -30 to 60 °C / -22 to 140 °F
Relative humidity
0 to 90 %, non-condensing
Input voltage
90-264 VAC, 47-63 Hz standard
Power consumption (W)
<300 (max) <300 (typical start-up) <200 (typical running)
Unit dimensions (width x height x depth)
457 x 834 x 254 mm 18.00 x 32.84 x 10.00 inch
Sampling probe compatibility
Installation options
IP 56 wall-mounted, sealed/purged enclosure
Hazardous area certifications
Legtöbbször letöltött
Raman Rxn5 Technical Information
System design and specifications for the Raman Rxn5 analyzer -
powered by Kaiser Raman technology
EN
HU
DE ES IT JA PT RU ZH
21/11/2023
Nyelv:
Angol
Változat:
21/11/2023
Fájlméret:
1.2 MB
Fájlnév:
TI01646CEN_0222.pdf
LNG parameters & calibration
Operating Instructions
A complete overview of the LNG parameters and calibration for the
Raman analyzer
Nyelv:
Angol
Változat:
21/08/2024
Fájlméret:
865.4 KB
Fájlnév:
BA02371CEN_0124.pdf
83 dokumentumok
Raman Rxn5 Technical Information
System design and specifications for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
EN
HU
Német Spanyol Olasz Japán Portugál Orosz Kínai
21/11/2023
Nyelv:
Angol
Változat:
21/11/2023
Fájlméret:
1.2 MB
Fájlnév:
TI01646CEN_0222.pdf
Raman RunTime v6.5 Operating Instructions
Commissioning, operation, and maintenance details for Raman RunTime v6.5 software
EN
HU
Német Japán
16/11/2023
16/11/2022
31/12/2020
Nyelv:
Angol
Változat:
16/11/2023
Fájlméret:
6.7 MB
Fájlnév:
BA02180CEN_0423.pdf
Raman Rxn5 Operating Instructions
Commissioning, operation, and maintenance details for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
EN
HU
Német Spanyol Olasz Japán Portugál Orosz Kínai
16/01/2025
21/11/2023
Nyelv:
Angol
Változat:
16/01/2025
Fájlméret:
4.6 MB
Fájlnév:
BA02179CEN_0425.pdf
LNG parameters & calibration
Operating Instructions
A complete overview of the LNG parameters and calibration for the Raman analyzer
Nyelv:
Angol
Változat:
21/08/2024
Fájlméret:
865.4 KB
Fájlnév:
BA02371CEN_0124.pdf
Raman Rxn5 Brief Operating Instructions
Quick start guide for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
EN
HU
Német Spanyol French Olasz Portugál Orosz Kínai
16/01/2025
21/11/2023
Nyelv:
Angol
Változat:
16/01/2025
Fájlméret:
2.3 MB
Fájlnév:
KA01554CEN_0325.pdf
LNG analyzer performance verification kit Installation Instructions
Instructions for use of the LNG analyzer performance verification kit
Nyelv:
Angol
Változat:
30/03/2023
Fájlméret:
442.7 KB
Fájlnév:
EA01470CEN_0123.pdf
Raman Rxn5 Safety Instructions
Hazardous area certifications and installation instructions for the Raman Rxn5 analyzer - powered by Kaiser Raman technology
EN
HU
Német Spanyol French Olasz Japán Koreai Portugál Orosz Kínai
07/12/2023
Nyelv:
Angol
Változat:
07/12/2023
Fájlméret:
1.6 MB
Fájlnév:
XA02746CEN_0222.pdf
石油・ガスおよび化学産業向け
ラマン分光計アプリケーションガイド
- ガスストリームおよびLNGの組成分析
化学産業および石油・ガス産業におけるガスストリームおよび LNG の組成分析用(Raman Rxn4 アナライザー、Raman Rxn5 アナライザ ー、Raman Rxn-30 プローブ、Raman Rxn-41 プローブを含む)、 Kaiser Raman テクノロジーによるラマン分光アナライザーおよび プローブ製品ラインアップのご案内です。
Nyelv:
Japán
Változat:
13/05/2024
Fájlméret:
4.2 MB
Fájlnév:
PU01445CJA_0121_RamanAnalyzer_AppGuide_OilGas_ChemInd.pdf
Raman Rxn5 analyzer - Laser-based composition analysis
An overview brochure about our Raman Rxn5 analyzer (including the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe), a Raman spectroscopy analyzer system for gas phase measurements powered by Kaiser Raman technology.
Nyelv:
Angol
Változat:
28/10/2021
Fájlméret:
499.9 KB
Fájlnév:
PU01444CEN_0121.pdf
Industry standards on gas quality - Raman Rxn5
analyzer (syngas/LNG) andRaman Rxn4 analyzer (LNG)
A list of industry gas quality standards that our Raman Rxn5 analyzer meets for syngas / LNG and our Raman Rxn4 analyzer meets for LNG.
Nyelv:
Angol
Változat:
20/04/2022
Fájlméret:
432.5 KB
Fájlnév:
PU01463CEN_0122.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
EO fiber cable pulling kit
Wireless keyboard with trackpad
Az adatvédelem nagyon fontos számunkra
Sütiket használunk a böngészési élmény javítására, statisztikai adatok gyűjtésére a webhely működésének optimalizálása érdekében, valamint személyre szabott hirdetések vagy tartalmak közvetítésére.
Ha az „Összes elfogadása” lehetőségre kattint, Ön hozzájárul a sütik használatához.
További részletekért kérjük, tekintse meg a sütikre (cookie) vonatkozó irányelveinket .
Testreszabás
Csak az alapvetőek elfogadása
Összes elfogadása